Skip to main content

FluxVM Secure Containers — Set 6

Set 6 focuses on restart safety and CNI dual-stack while preserving the Set 5 VSOCK/PTY data path.

Recovery journal​

Each runtime group stores a versioned journal at:

$FLUXVM_CONTAINERD_STATE_DIR/<namespace>/<group>/runtime-state.json

The journal records the FluxVM VM identity, CNI bridge/netns metadata, Pod share paths, init task metadata and exec metadata. Writes are atomic (temp-file + rename).

As soon as FluxVM returns a new VM ID, the shim writes ready=false ownership before waiting for guest boot. Once guest networking, virtiofs mounts and the container agent are ready, the journal becomes ready=true.

A replacement shim can recover only when it can prove that:

  • the recorded VM still exists and its name matches;
  • the recorded CNI host bridge/veth and netns bridge/veth still exist;
  • the FluxVM guest agent responds;
  • required virtiofs shares are mounted; and
  • the secure-container agent is available for any recorded live process.

If live task metadata exists and those checks fail, the shim fails closed. It will not cold-create a second VM for the same Pod.

A corrupt or unsupported journal also fails closed. Operators can disable journal recovery with FLUXVM_CONTAINER_RECOVER=0, but should only do so after they have independently established that no journal-owned VM is still alive.

containerd supervision is separate from runtime state recovery. Set 6 makes a replacement shim safe to attach; it does not claim that every stock containerd configuration automatically respawns an abruptly killed shim.

Re-attachable VSOCK streams​

Set 5 introduced streaming stdio on VSOCK port 17779. Set 6 keeps the guest pipe/PTY endpoints owned by fluxvm-container-agent and duplicates file descriptors for each successful attachment. When a transport disconnects its attachment flag is released so a replacement shim can attach again.

For stdin, transport EOF does not close the OCI process input. Only containerd CloseIO performs the explicit EOF operation. This prevents a temporary shim/socket loss from permanently closing interactive input.

Dual-stack CNI​

Set 6 captures every routable IPv4 and IPv6 address on the configured primary CNI interface plus family-specific routes. The guest receives the same addresses and routes, and teardown restores both families into the Pod netns.

IPv6 address replay uses nodad because the CNI plugin already owned and validated the address before FluxVM moved the L2 endpoint into the guest.

Multi-interface / Multus guard​

A single FluxVM guest NIC currently represents the primary CNI endpoint. If the Pod netns already contains another interface with a routable IPv4/IPv6 address, Set 6 rejects the sandbox by default rather than silently dropping the secondary network.

Cilium exception: when FLUXVM_CONTAINER_CNI_PROVIDER resolves to cilium (or auto detects Cilium), Multus-style netN secondaries are ignored for the strict check so the primary eth0 L2 handoff can proceed. They are then attached to the guest as extra NICs over their own bridge chains (Set 7R follow-up; the Set 6 behavior of leaving them unattached is superseded). See cilium-cni.md.

For controlled labs only:

export FLUXVM_CONTAINER_CNI_STRICT_MULTI_INTERFACE=0

Real Multus support should add explicit secondary NIC hotplug/rebind instead of using that escape hatch in production.

Warm-pool decision​

FluxVM has paused VM pools, but current pool claims override only name and TTL. Secure Containers needs Pod-specific CNI topology and Pod-specific virtiofs shares, which are fixed at VM creation today. Reusing such a pool member across Pods would break isolation.

Set 6 therefore instruments cold-start and recovered-sandbox latency but does not use the existing VM pool API. A later performance set should first add safe NIC/share rebinding or hotplug.

Suggested node tests​

sudo ./scripts/e2e-secure-containers-dualstack.sh
./scripts/inspect-secure-container-recovery.sh